Page 163 - Jewell Inertial Sensor Catalog
P. 163

LCF-200 Series Flexure Suspension                                              Making Sense out of Motion…

      LCF-200 Series Accelerometer Specifications

STATIC/DYNAMIC                                            ±0.5                   ±1      ±2      ±5
                                                         ±5.00                 ±5.00   ±5.00   ±5.00
Input Range, g:
Full Range Output (FRO -Note 1) VDC ±0.5%:                 10                     5      2.5      1
Scale Factor, Volts/g, nominal:                           100                   100     100     100
Scale Factor Temp. Sensitivity (SFTS), PPM /°C maximum:  30.00                 30.00   30.00   30.00
Natural Frequency, Hz nominal (Note 3):                   30.0                  30.0    30.0    30.0
Bandwidth (-3 dB), Hz nominal:                            0.71                  0.71    0.71    0.71
Output Axis Misalignment, ° maximum:                      0.71                  0.71    0.71    0.71
Pendulous Axis Misalignment, ° maximum:                  ±0.005                ±0.005  ±0.005  ±0.005
Bias, g range:                                             50                    50      50      50
Bias Temperature Sensitivity, µg /°C maximum:
Resolution and Threshold, µg maximum:                       1                     1       1       1

ELECTRICAL                              1                ENCLOSURE                          4
                                   ±12 to ±18                                  MIL-STD-202, Mtd. 112
Number of Axes:                                          Weight oz:
Input Voltage Range, (VDC):             15               Seal:
Input Current, mA, max:                100
Output Impedance, Ohms, nom:          0.001
Noise, grms, maximum:

ENVIRONMENTAL                          -40°C to +80°C
                                       -40°C to +90°C
Operating Temp Range:
Storage Temp Range:                            20
Vibration grms:               1000 g, 1 msec, ½ sine
Shock:

Notes:  1 - Full range is defined as "from negative full input acceleration."
        2 - Referenced to best-fit straight line independent of misalignment.
        3 - Output phase angle = -90°.

How to Order

LCF-200-.5g            458200-001
LCF-200-1.0g           458200-004
LCF-200-2.0g           458200-002
LCF-200-5.0g           458200-003

          Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
   158   159   160   161   162   163   164   165   166   167   168