Page 185 - Jewell Inertial Sensor Catalog
P. 185
DXA-100/200-R Series Accelerometer
Making Sense out of Motion…
Performance ±0.25 ±0.50 ±0.87 ±1.00 ±2.00
1,2 1,2 1,2 1,2 1,2
Input Range¹, g 0.02 0.02 0.03 0.05 0.03
Number of Axis 0.05 0.05 0.05 0.05 0.05
Non Linearity², %FRO, Max 1.00 1.00 1.00 1.00 1.00
Scale Factor Tolerance, % Max 90 90 90 90 90
Bias, mg 30 30 30 30 30
Bias Thermal Sensitivity, mg 0.5 0.5 0.5 0.5 0.5
Bandwidth (-3dB), Hz, Nom³
Transverse Axis Misalignment, °, Max
Digital Output EIA-RS485 (default)/EIA-RS422
Interface Proprietary (Custom)
Protocol
Output Representation g's
Baud Rateâ´
19200 38400 57600 115200 230400
Electrical
Supply Voltage, Volts DC 10 to 30
DXA-100-R 32 mA/DXA-200-R 50 mA
Input Current, mA, Max Transmitting DXA-100-R 22 mA/DXA-200-R 40 mA
Not transmitting -40 to +85
-40 to +85
Environmental
IP67
Operational Temp Range, °C 6
Storage and Temp Range, °C 1500g, 1msec, ½ sine
20
Protection Class per IEC 529
NEMA Enclosure Rating
Shock Survival
Vibration Survival, grms (20Hz to 2 KHz)
Enclosure
Housing Material Anodized Aluminum
Weight DXA-100-R 8 oz [226.80 g]/ DXA-200-R 10 oz [283.50 g]
Connector Type MS27476Y10D35P
Recommended Mating Connector MS27473T10B35S
NOTES: 1- Full range is defined as "from negative full input angle to positive full input angle"
2 - Non-linearity is specified as deviation of output referenced to a best fit straight line, independent of misalignment.
3 - In default condition without averaging.
4- Default Baud Rate is 38400
*Specifications subject to change without notice on account of continued product development
Meets CENELEC/AREMA Standards
CENELEC EN 55022:2010
CENELEC EN 50155:2007
CENELEC EN 61000-4-8:2010
AREMA Part 11.5.1
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955