Page 21 - Jewell Inertial Sensor Catalog
P. 21

Analog MEMS Inclinometers

                                                 AMH Series                        AMI Series                                       AMV Series

Features & Benefits                       •	Single and Dual Axis Available  •	Single and Dual Axis Available                 •	Single and Dual Axis Available
Applications                              •	Resolution <0.001°                                                               •	Resolution <0.001°
Performance Specs                                                           •	Resolution <0.001°                             •	 Zero Temp Coefficient ±0.005°/°C
Static/Dynamic                            •	 Zero Temp Coefficient ±0.006°/°C •	 Zero Temp Coefficient ±0.002°/°C            •	Excellent Performance over Temp
                                          •	High Shock & Vibration Tolerance •	Excellent Performance over Temp               •	Analog ±5V & ±10V	
                                          •	Analog 0-5V, 0.5-4.5V & 4-20mA •	Analog 0-5V, 0.5-4.5V & 4-20mA 	
                                          Output Options                    Output Options                                      Output Options
                                          •	−40° to +85°C Temp Range	       	 •	−40° to +85°C Temp Range	                    •	−40° to +85°C Temp Range	

                                                                            		                                                  		
                                          •	Radar & Vehicle Platform Leveling •	Radar & Vehicle Platform Leveling            •	Radar & Vehicle Platform Leveling
                                          •	Drill Rig Alignment             •	Drill Rig Alignment                            •	Drill Rig Alignment
                                          •	 Offshore/Subsea Platform Pitch & Roll •	 Offshore/Subsea Platform Pitch & Roll  •	 Offshore/Subsea Platform Pitch &
                                          •	Industrial Measurement & Control •	Industrial Measurement & Control
                                                                                                                                Roll
                                                                                                                             •	Industrial Measurement &

                                                                                                                                Control

Angular Range1 (°):                        ±10       ±30         ±60         ±10    ±30             ±60                       ±10      ±30                                   ±60
                                          0.005                  0.01       0.003                  0.008                     0.003                                           0.02
Resolution (°) :                                  0.001                             0.001                                            0.001
Hysteresis:                                         0.008                          0.005                                              0.01
Zero Temp Coefficient, °/°C :                    ±0.006                            ±0.002
Scale Factor Temp Coefficient (PPM/°C) :                                                                                            ±0.005
Warm Up (s) :                                     <200                               <50                                              <50
Time Constant (s) :                                 0.5                               0.5                                             0.5
                                                   0.05                              0.02                                            0.02

Electrical & Environmental                0-5V, 0.5 - 4.5V or 4-20mA        0-5V, 0.5 - 4.5V or 4-20mA                                ±5V & ±10V

  Output :                                EN61000 and GBT17626              EN61000 and GBT17626                             EN61000 and GBT17626
  Output Type2:                           100g@11ms, 3 times/axis           100g@11ms, 3 times/axis                          100g@11ms, 3 times/axis
  Electromagnetic Compatibility :
  Impact Resistance :                              (½ sinusoid)                      (½ sinusoid)                                    (½ sinusoid)
                                            10grms @ 10-1000Hz                 10grms @ 10-1000Hz                              10grms @ 10-1000Hz
  Vibration Resistance :
  Temperature Rating, Operation :                -40 to +85°C                       -40 to +85°C                                     -40 to +85°C
  Temperature Rating, Storage :                  -55 to +100°C                     -55 to +100°C                                    -55 to +100°C
  Enclosure :                                Anodized Aluminum                  Anodized Aluminum                                Anodized Aluminum
  Seal :
  Cables :                                             IP67                               IP67                                            IP67
  Weight :                                   1m Cable (standard)               2m Cable (standard)                              2m Cable (standard)
  Power Requirements :                       150g (without cable)              150g (without cable)                             150g (without cable)
                                              9-36 VDC @ 60mA                    9-36 VDC @ 60mA                                  9-36 VDC @ 60mA

Notes: 1 - Full range is defined as “from negative full input angle to positive full input angle.”  The inclinometer output is proportional to the sine of the tilt angle.,
        2 - Referenced to theoretical sine value independent of misalignment., 3 - Output phase angle = -90° 4 - Other ranges available upon request
   16   17   18   19   20   21   22   23   24   25   26