Page 213 - Jewell Inertial Sensor Catalog
P. 213
QFA-125-30-LC Series High Temperature, Low Input Current
Quartz Flexure Accelerometer
Making Sense out of Motion…
Performance Specifications ±30
1.1 to 1.4
Performance
40
Acceleration Range, g Max. (Note 1) 1.5
Scale Factor, mA/g (Note 2) 10
Bias, milli-g, Max. (@ 25° C) 300
Axis Alignment, mRad, Max. (@ 25° C)
Threshold and Resolution, µg, Max. ±200
Bandwidth, Hz, Min. ±170
Scale Factor Temp. Sens, PPM/°C, Max. (Note 3): ±100
less than 250 ppm
+55°C to +180°C less than 250 ug
+100°C to +180°C
Bias Temp. Sens, µg/°C, Max. 3
Scale Factor Stability (1 month composite) 55
Bias Stability (1 month composite)
Noise, mgrms, Max. (0Hz to 10kHz) (Max.)
Weight (grams)
Electrical ±12 to ±18
+/-13mA max @ +/-18Vdc input
Input Voltage, Vdc +/- 10mA nominal @ +/-15Vdc input
Input Current, mA +/- 8mA nominal @ +/-12Vdc input
External Load Resistor Dependent
Output Impedance, ohms
Environmental -55°C to +125°C
25 Hz to 500 Hz, 25g
Operational Temp Range, °C 50 Hz to 500 Hz, 100 ug/g²rms
Vibration, (Sine)
Vibration, (Random) Rectification, ug/g²rms 1000
Shock, g (0.5 msec, 1/2 sine)
Note 1: Specifications apply and are characterized up to ±1g range. The accelerometer is capable of supplying acceleration
information up to ±30g but at reduced accuracy.
Note 2: Voltage output via customer supplied load resistor.
Note 3: Scale factor shown in mA/g as a standard. If you require scale factor in volts/g, please specify voltage range when ordering
*Specifications subject to change without notice on account of continued product development
How to Order Part # Accelerometers exported from the United States must be
848 205-002 done in accordance with the Export Administration
Model # 848 206-002 Regulations (EAR) and/or the International Traffic in Arms
QFA-125-30G-SQ-LC Regulations (ITAR) as applicable.
QFA-125-30G-RD-LC
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
Rev 2