QFA-125-30-LC Series High Temperature, Low Input Current
                  Quartz Flexure Accelerometer

                                                                              Making Sense out of Motion…

Performance Specifications                                ±30
                                                      1.1 to 1.4
Performance
                                                          40
Acceleration Range, g Max. (Note 1)                       1.5
Scale Factor, mA/g (Note 2)                               10
Bias, milli-g, Max. (@ 25° C)                             300
Axis Alignment, mRad, Max. (@ 25° C)
Threshold and Resolution, µg, Max.                       ±200
Bandwidth, Hz, Min.                                      ±170
Scale Factor Temp. Sens, PPM/°C, Max. (Note 3):          ±100
                                                 less than 250 ppm
               +55°C to +180°C                    less than 250 ug
               +100°C to +180°C
Bias Temp. Sens, µg/°C, Max.                               3
Scale Factor Stability (1 month composite)                55
Bias Stability (1 month composite)
Noise, mgrms, Max. (0Hz to 10kHz) (Max.)
Weight (grams)

Electrical                                                       ±12 to ±18
                                                   +/-13mA max @ +/-18Vdc input
Input Voltage, Vdc                               +/- 10mA nominal @ +/-15Vdc input
Input Current, mA                                +/- 8mA nominal @ +/-12Vdc input
                                                  External Load Resistor Dependent
Output Impedance, ohms

Environmental                                             -55°C to +125°C
                                                       25 Hz to 500 Hz, 25g
Operational Temp Range, °C                       50 Hz to 500 Hz, 100 ug/g²rms
Vibration, (Sine)
Vibration, (Random) Rectification, ug/g²rms                   1000
Shock, g (0.5 msec, 1/2 sine)

Note 1: Specifications apply and are characterized up to ±1g range. The accelerometer is capable of supplying acceleration
            information up to ±30g but at reduced accuracy.

Note 2: Voltage output via customer supplied load resistor.
Note 3: Scale factor shown in mA/g as a standard. If you require scale factor in volts/g, please specify voltage range when ordering

          *Specifications subject to change without notice on account of continued product development

How to Order            Part #                   Accelerometers exported from the United States must be
                        848 205-002              done in accordance with the Export Administration
Model #                 848 206-002              Regulations (EAR) and/or the International Traffic in Arms
QFA-125-30G-SQ-LC                                Regulations (ITAR) as applicable.
QFA-125-30G-RD-LC

          Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955

                                                                                    Rev 2