      Performance Specifications

STATIC/DYNAMIC                                                           ± 1.0     ± 3.0             ± 14.5    ± 30.0    ± 90.0
                                                                        4 to 20   4 to 20           4 to 20   4 to 20   4 to 20
Input Range (°) (Note 1)
Full Range Output (FRO), mADC ± 1.0%                                      0.05      0.05              0.10      0.10      0.05
Non Linearity (%FRO, Max.) (Note 2)                                       458      152.8              31.3      16.0      8.0
Scale Factor, Ma/G (Nominal)                                              400       300               100       100       100
Scale Factor Temp Sens (PPM/°C, Max.)                                      0.3                         15        20        30
Natural Frequency, Hz (Nominal) (Note 3)                                   0.3       2.0               15        20        30
Bandwidth (-3dB), Hz (Nominal)                                            0.15       2.0              0.50      1.00      1.00
Transverse Axis Misalignment, ° Max.                                    12 ± 0.6    0.25            12 ± 0.3  12 ± 0.3  12 ± 0.3
Output at Zero Tilt, Ma                                                  0.015    12 ± 0.6          0.0032    0.0032    0.0016
Zero Tilt Temp Sens, mA/°C Max.                                                     0.01                                    1
Resolution and Threshold, μ rad Max.                                        1         1                 1         1

ELECTRICAL                                        ENVIRONMENTAL

Input Voltage, VDC         20 to 30 (24 Nominal)  Operating Temp Range                                      -18 to +71°C
                                                                                                            -40 to +71°C
Input Current (mA, Max.):                 40      Survival Temp Range
                                                                                                               20 grms
Noise, mA rms Max.                0.01 Vibration                                                     1500g, 0.5 msec, ½ sine
                                                                                                    MIL-STD 202, Method 112
                                                  Shock

                                                  Seal

Notes: 1 - Full range is defined as "from negative full input angle to positive full input angle."

The inclinometer output is proportional to the sine of the tilt angle.

2 - Referenced to theoretical sine value independent of misalignment.
3 - Output phase angle = -90°.

Custom Capabilities

• Internal temperature sensor and thermal modeling for the highest levels of accuracy over
   a wide temperature range

• Available in LSR Series package configuration for applications requiring a more compact solution
• Factory set zero biasing for non-horizontal measurements
• Solder terminals and flying leads in place of military connector
• Custom input ranges from ±0.5° to ±90° available
• Custom output impedances available

How to Order        02550278-506
                    02550278-507
LCOC-1L             02550278-508
LSOC-3L             02550278-509
LSOC-14.5L          02550278-510
LSOC-30L
LSOC-90L

          Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103